Among the hearing loss patients, we can confirm that the hearing loss of the specific frequency decreases, such as the 2000Hz notch in otosclerosis and the 4000Hz notch (c5-dip) in noise-induced hearing loss. The 1000Hz notch (c3-dip), however, is rarely studied. We fortuitously encountered a group of patients with a 1kHz hearing loss and report it with a review of the literature.