Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τετάρτη 8 Νοεμβρίου 2017

A biolayer interferometry-based enzyme-linked aptamer sorbent assay for real-time and highly sensitive detection of PDGF-BB

S09565663.gif

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Shunxiang Gao, Xin Zheng, Jihong Wu
Accurate, fast and sensitive detection of disease-specific protein biomarkers, especially in blood, urine, or other bodily fluids, is an important approach to achieve early disease diagnosis. Platelet-derived growth factor-BB (PDGF-BB), a widely used biomarker, is involved in a substantial number of serious diseases, such as hepatic fibrosis, atherosclerosis, age-related macular degeneration and diabetic eye disease and is often over-expressed in human malignant tumors. Therefore, the development of sensitive and specific detection methods for PDGF-BB is of great importance for the early diagnosis of disease and assessments of patient recovery. In the current study, a biolayer interferometry-based enzyme-linked aptamer sorbent assay (BLI-ELASA) was successfully established for rapid (20–25min), high-throughput (8 or 16 samples) and real-time monitoring of PDGF-BB in clinical samples. The method exhibited a broad detection range from 0.5 to 1000ng/mL of PDGF-BB (good linear range from 0.5 to 10ng/mL), with a low detection limit of 0.08ng/mL. Moreover, BLI-ELASA was applied to the detection of PDGF-BB in spiked serum and urine samples and showed a high degree of selectivity for PDGF-BB, good reproducibility, and stability. We believe that the methodology in this work can be easily adapted to detect other biomolecules in clinical samples, including viruses, pathogens and toxins, in a rapid, sensitive, high-throughput and real-time manner.



http://ift.tt/2ArTWaV

Creation of antifouling microarrays by photopolymerization of zwitterionic compounds for protein assay and cell patterning

S09565663.gif

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Xiuhua Sun, Huaixin Wang, Yuanyuan Wang, Taijiang Gui, Ke Wang, Changlu Gao
Nonspecific binding or adsorption of biomolecules presents as a major obstacle to higher sensitivity, specificity and reproducibility in microarray technology. We report herein a method to fabricate antifouling microarray via photopolymerization of biomimetic betaine compounds. In brief, carboxybetaine methacrylate was polymerized as arrays for protein sensing, while sulfobetaine methacrylate was polymerized as background. With the abundant carboxyl groups on array surfaces and zwitterionic polymers on the entire surfaces, this microarray allows biomolecular immobilization and recognition with low nonspecific interactions due to its antifouling property. Therefore, low concentration of target molecules can be captured and detected by this microarray. It was proved that a concentration of 10ngmL−1 bovine serum albumin in the sample matrix of bovine serum can be detected by the microarray derivatized with anti-bovine serum albumin. Moreover, with proper hydrophilic-hydrophobic designs, this approach can be applied to fabricate surface-tension droplet arrays, which allows surface-directed cell adhesion and growth. These light controllable approaches constitute a clear improvement in the design of antifouling interfaces, which may lead to greater flexibility in the development of interfacial architectures and wider application in blood contact microdevices.



http://ift.tt/2jc4OFE

Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Kaixin Zhang, Guozhen Liu, Ewa M. Goldys
Detection of a very low amount of cytokines such as interleukin-6 (IL-6) in clinical fluids is important in biomedical research and clinical applications. Here, we demonstrate spatially-localized ultrasensitive (femtogram mL−1) level detection of IL-6 in serum and in cell culture media. Our approach is based on a sandwich immunosensor fabricated on the surface of an optical fibre. Firstly, the biotinylated IL-6 capture antibody was immobilized on the fibre surface by biotin-streptavidin coupling. Then the fabricated fibre was used for capturing IL-6 followed by exposure to detection antibody which was labeled with the fluorescent magnetic nanoparticles to report the signal. A linear relationship between IL-6 concentration and the fluorescence signal was obtained in the range from 0.4pgmL−1 to 400pgmL−1 of IL-6, with the limit of detection down to 0.1pgmL−1. In addition, this optical fibre sensor was successfully applied for the localized detection of IL-6 with the spatial resolution of 200µm and a sample volume of 1µL. Finally, the performance of the fibre sensor was demonstrated by detection of IL-6 secreted by BV-2 cells with comparable performance of the conventional enzyme-linked immunosorbent assay (ELISA).

Graphical abstract

image


http://ift.tt/2AvifVk

A reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue to DNA with alternating AT base sequence for sensitive detection of adenosine

S09565663.gif

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Lin Cui, Mengfei Lu, Ying Li, Bo Tang, Chun-yang Zhang
We develop a reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue (MB) to DNA with alternating AT base sequence for sensitive detection of adenosine. We design a strand 1 with MB-modified thymine (T) base in the proximal 3′ termini as the capture probe for its immobilization on the gold electrode and a 3′ termini ferrocene (Fc)-modified aptamer for the recognition of adenosine. The hybridization of strand 1 with the aptamer leads to the formation of a double-stranded DNA (dsDNA) and consequently the away of MB from the electrode surface and the close of Fc to the electrode surface, generating a small value of IMB/IFc (IMB and IFc are the peak currents of MB and Fc, respectively). In the presence of adenosine, its binding with the aptamer induces the release of Fc from the electrode surface and the close of MB to the electrode surface, generating a large value of IMB/IFc. As a result, adenosine may be accurately quantified by the measurement of ratiometric signal (IMB/IFc). This ratiometric electrochemical biosensor can be simply fabricated and exhibits high sensitivity with a limit of detection of as low as 90.8pM and a large dynamic range from 0.1nM to 100μM. Moreover, this biosensor demonstrates good performance with excellent selectivity, regeneration capability, high reliability and good reproducibility, and may become a universal platform for the detection of various biomolecules which can be recognized by aptamers, holding great potential for further applications in biomedical research and clinical diagnosis.



http://ift.tt/2AtUXiT

Cerium dioxide-doped carboxyl fullerene as novel nanoprobe and catalyst in electrochemical biosensor for amperometric detection of the CYP2C19*2 allele in human serum

S09565663.gif

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Chengli Zhang, Junlin He, Yuchan Zhang, Jun Chen, Yilin Zhao, Yazhen Niu, Chao Yu
The disposition dose of clopidogrel is different in CYP2C19*2 gene carriers and non-carriers. High-dose clopidogrel has been recommended to overcome a low-responsiveness to clopidogrel in patients with the CYP2C19*2 gene. To guide the choice of clopidogrel dosage and catalyse a development in the field of personalized therapy, we developed an ultrasensitive electrochemical biosensor to detect CYP2C19*2 gene. We constructed a novel assay based on cerium dioxide (CeO2)-functionalized carboxyl fullerene (c-C60) supported by Pt nanoparticles (c-C60/CeO2/PtNPs) for signal amplification. Au nanoparticles @ Fe-MIL-88NH2 (AuNPs@Fe-MOFs) were synthesized by one-step method as the support platform to enhance the conductivity and immobilize more biotin-modified capture probe (bio-CP) through the superior affinity and specificity between streptavidin and biotin. c-C60/CeO2/PtNPs were labeled with signal probe to form the signal label. After the sandwich reaction of CYP2C19*2 gene between capture probe and the signal label, a distinguishing electrochemical signal from the catalysis of H2O2 by signal label would be observed. Amperometry was applied to record electrochemical signals. Under optimized conditions, the approach showed a good linear dependence between current and the logarithm of CYP2C19*2 gene concentrations in the range of 1 fM to 50nM with a low detection limit of 0.33fM (S/N = 3). The proposed method showed good specificity to target DNA compared with possible interfering substances. More importantly, the fabricated biosensor achieved accurate quantitative detection of CYP2C19*2 gene in human serum samples demonstrated by excellent correlations with standard DNA sequencing and provided a promising strategy for electrochemical biosensor detection of other gene mutations.



http://ift.tt/2jbhay4

Highly efficient charge transfer in Co/Co2P Schottky junctions embedded in nitrogen-doped porous carbon for enhancing bioelectricity generation

S09565663.gif

Publication date: 15 April 2018
Source:Biosensors and Bioelectronics, Volume 102
Author(s): Xin Xu, Shijie You, Liu Yang, Zipeng Xing, Siyu Pan, Zhuang Cai, Ying Dai, Jinlong Zou
Exploration of noble-metal free catalysts with high oxygen reduction reaction (ORR) activity and durability as alternatives for platinum/carbon (Pt/C) in microbial fuel cells (MFCs) remains a great challenge. This study reports the preparation of nitrogen-doped cobalt/cobalt phosphide/carbon (Co/Co2P/NC) catalysts via an in situ simultaneous doping/reduction method by using residual cornstalks as carbon source. Effects of carbonization temperature on structural characteristics and catalytic activity of Co/Co2P/NC catalysts are investigated. Co/Co2P/NC-850 with regular network structure obtains the maximum power density of 972 ± 5mWm−2, which is higher than that of Pt/C (808 ± 5mWm−2). The highest Coulombic efficiency (23.1%) and the lowest charge transfer resistance (0.93Ω) are also obtained by Co/Co2P/NC (850°C). ORR catalyzed by Co/Co2P/NC-850 is mainly via 4e− reduction pathway. The better durability of Co/Co2P/NC (850°C) is detected from long-term operation of MFCs. The promising catalytic activity for ORR is attributed to the introduction of Co/Co2P nanoparticles/Schottky junctions and N species in porous carbon skeleton, which are served as active sites to trap and consume electrons. Biomass-derived carbon with good electrical conductivity can provide large specific surface area and abundant interconnected holes, which contribute to efficient permeation and transport of O2. The synergistic effects between porous structure and sufficient active sites can energetically boost catalytic activity to improve ORR efficiency. These Co/Co2P/NC catalysts with durable power outputs are expected to have more extensive applications in MFCs.



http://ift.tt/2AuYVb4

Photolytic degradation of ciprofloxacin in solid and aqueous environments: kinetics, phototransformation pathways, and byproducts

Abstract

Many lipophilic pharmaceuticals may be sorbed in solid phases, leading to different photochemical behaviors. This study investigated the photochemistry of ciprofloxacin in a solid-phase system and compared it to that in a water-phase system. Kaolinite was used as the model solid matrix. The photolysis of ciprofloxacin in kaolinite fits pseudo-first-order kinetics for thicknesses less than 199 μm, and the rate constants k p decreased from 0.0154 to 0.0016 min−1 as the thickness of the layer increased. Unlike the aqueous phase, two-step degradation processes were observed for all kaolinite layer thicknesses (14–199 μm), and the pseudo-first-order constant at the surface of the kaolinite layer was smaller than that in the water phase. Comparatively, a similar photolysis rate constant of ciprofloxacin in a kaolinite suspension was also observed, and it was an order of magnitude smaller than that of the direct photodegradation (0.035 min−1) in water. The results indicate that ciprofloxacin is likely more stable when it is adsorbed on kaolinite and that the half-lives of ciprofloxacin in kaolinite and a kaolinite suspension are 2–25 times longer than that in deionized water (20 min) under simulated sunlight. Direct photolysis is proposed to be the main photodegradation mechanism for ciprofloxacin in kaolinite, and the cleavage of a piperazine ring is the main degradation pathway. However, the interaction between ciprofloxacin and kaolinite reduces the direct photolysis and leads to a higher light stability. In association with the reduction in photolysis, the yields of norfloxacin and defluorinated byproduct decreased significantly. Consequently, the interaction increases the persistence of ciprofloxacin and thus the ecological risk to the environment.



http://ift.tt/2zHQdsH

Αρχειοθήκη ιστολογίου