Symmetry of cortical planning for initiating stepping in sub-acute stroke

elsevier-non-solus.png

Publication date: April 2018
Source:Clinical Neurophysiology, Volume 129, Issue 4
Author(s): Sue Peters, Tanya D. Ivanova, Bimal Lakhani, Lara A. Boyd, W. Richard Staines, Todd C. Handy, S. Jayne Garland
ObjectiveThis study examined motor planning for stepping when the paretic leg was either stepping or standing (to step with the non-paretic leg), to understand whether difficulty with balance and walking post-stroke could be attributed to poor motor planning.MethodsIndividuals with stroke performed self-initiated stepping. Amplitude and duration of the movement-related cortical potential (MRCP) was measured from Cz. Electromyography (EMG) of biceps femoris (BF) and rectus femoris (RF) were collected.ResultsThere were no differences between legs in stepping speed, MRCP or EMG parameters. The MRCPs when stepping with the paretic leg and the non-paretic leg were correlated. When the paretic leg was stepping, the MRCP amplitude correlated with MRCP duration, indicating a longer planning time was accompanied by higher cognitive effort. Slow steppers had larger MRCP amplitudes stepping with the paretic leg and longer MRCP durations stepping with the non-paretic leg.ConclusionsMRCP measures suggest that motor planning for initiating stepping are similar regardless of which limb is stepping. Individuals who stepped slowly had greater MRCP amplitudes and durations for planning.SignificanceIndividuals who step slowly may require more time and effort to plan a movement, which may compromise their safety in the community.



http://ift.tt/2CzEoSm

Shear wave elastography in the diagnostics of parathyroid adenomas–new application of the method

Abstract

Purpose:

Shear wave elastography (SWE) was described as valuable tool in the diagnostics of distinct types of thyroid lesions, thyroiditis and several other non-thyroidal conditions, such as liver inflammation and fibrosis or diagnostics of breast lesions. The aim of the current study was to assess the appearance of parathyroid adenomas in SWE and to check prospectively if SWE can be valuable additional tool in the diagnostics of pathologically enlarged parathyroids.

Methods:

Patients with parathyroid adenomas confirmed by histopathology were included. Subjects with benign thyroid lesions were enrolled to the control group. Elasticity of parathyroid adenomas and benign thyroid nodules was measured and compared.

Results:

Sixty five patients with parathyroid adenomas and 35 patients with 51 benign thyroid nodules were included. Parathyroid adenomas where significantly more elastic than benign thyroid nodules–mean elasticity of the lesion was 5.2 ± 7.2 vs. 24.3 ± 33.8 kPa, respectively. Relative mean elasticity (in comparison with surrounding thyroid tissue) was 0.30 ± 0.36 and 2.8 ± 3.9, respectively.

Conclusions:

SWE can be useful tool in the diagnostics of parathyroid adenomas. Enlarged parathyroids are significantly more elastic than benign thyroid lesions. Low elasticity of the lesion constitutes feature with high negative prognostic value, allowing for reliable exclusion of suspicion of parathyroid adenomas.



http://ift.tt/2EFuAIs

Orbital exenteration for sinonasal malignancies: indications, rehabilitation and oncologic outcomes

Purpose of review Review the recent literature regarding the management of orbital invasion in sinonasal malignant tumors. Recent findings There is a recent trend in preserving the orbit in cases of minimal invasion of periosteum and limited periorbit involvement, as well as in presence of good response to neoadjuvant chemotherapy, mainly in squamous cell carcinoma and neuroendocrine histologies. Summary The decision about orbital exenteration in cases of sinonasal malignancies is facilitated if the patient already has clear clinical signs of intraconal invasion such as visual loss, restriction of ocular mobility or infiltration of the eyeglobe. However, in borderline situations, confirmation of orbital involvement should be performed intraoperatively. In selected cases with minimal orbital invasion without functional compromise, orbit sparing surgery can be done with acceptable oncological outcomes. Correspondence to Luiz P. Kowalski, MD, PhD, Head and Neck Surgery and Otorhinolaryngology Department, A.C. Camargo Cancer Center, Rua Professor Antonio Prudente, 211, 01509900 Sao Paulo, Brazil. Tel: +55 11 2189 5172; e-mail: lp_kowalski@uol.com.br Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.

http://ift.tt/2Gzx23H

Perspectives on voice treatment for unilateral vocal fold paralysis

Purpose of review Unilateral vocal fold paralysis (UVFP) is a common cause of neurogenic dysphonia resulting in glottal insufficiency. To restore glottal sufficiency and reduce the presenting dysphonia, treatment involving either surgical intervention, voice therapy or a combination of the two is typically provided. Currently, there is no consensus for the most effective voice treatment for UVFP. This results in an inability to compare current studies, and a lack of treatment effectiveness for the management of UVFP. This study aims to review the most recent literature for the management of dysphonia due to UVFP to establish the current evidence base for voice treatment options. Recent findings There was found to be a lack of consistency in the rationale, selection and timing of the surgical intervention and/or voice therapy being provided for patients with UVFP. Summary Further consensus is required for the rationale and selection of voice treatment prescriptions for the management of UVFP in order to improve treatment effectiveness and voice outcomes in patients with UVFP. Correspondence to Chloe Walton, Australian Catholic University (ACU), 1100 Nudgee Road, Banyo, QLD 4014, Australia. Tel: +07 3623 7100; e-mail: Chloe.walton@acu.edu.au Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.

http://ift.tt/2FiOgCR

Transition in microstructural and mechanical behavior by reduction of sigma-forming element content in a novel high entropy alloy

Publication date: 5 May 2018
Source:Materials & Design, Volume 145
Author(s): Ahmad Raza, Byungchul Kang, Junho Lee, Ho Jin Ryu, Soon Hyung Hong
A novel CrFeMoVMnx high entropy alloy (HEA) system was devised after screening done with thermodynamic constraints. The Mn content was varied (x=0, 0.5, 1 atomic ratio), with other elements kept in equiatomic ratios, to determine the effect of paired sigma-forming element (PSFE) content on microstructural and mechanical behavior. Alloys were successfully fabricated using a powder metallurgical method after mechanical alloying (MA) for an optimized minimum milling time. The milled powder was sintered using spark plasma sintering (SPS). The microstructural analysis indicated the appearance of a σ phase in the equiatomic quinary CrFeMoVMnx system, and the volume fraction of the σ phase varied directly by Mn content. The Mn0 system exhibited the formation of a single phase solid solution. The failure of thermodynamic prediction, the role of PSFE content and Md¯ in σ phase appearance were investigated. The transition in mechanical behavior through a reduction in Mn content was also investigated and Mn1 exhibited the highest fracture strength, of 3183MPa, and hardness of 868 Hv, while Mn0 displayed the highest plasticity. This study demonstrates higher specific yield strength and hardness values compared to previously reported HEA systems.

Graphical abstract

image


http://ift.tt/2Czx2yp

Selective laser melting of stainless steel and alumina composite: Experimental and simulation studies on processing parameters, microstructure and mechanical properties

Publication date: 5 May 2018
Source:Materials & Design, Volume 145
Author(s): Xinwei Li, Habimana Jean Willy, Shuai Chang, Wanheng Lu, Tun Seng Herng, Jun Ding
Metal matrix composites (MMC) find their uses as high performance materials. The selective laser melting (SLM) of a 316L stainless steel and Al2O3 MMC is presented in this paper. Agglomerate Al2O3 particles had shown to be an adequate powder choice with uniform dispersions in the resultant prints. Relative density, phase, microstructure and mechanical properties of all 1-, 2-, 3-wt% doped products were carefully analyzed. Finite element modeling model was developed to study the associated multi-physics phenomena with high efficiency for process parameter optimization. It is found that the change in SLM temperature profile with Al2O3 addition is mainly due to the change in optical properties rather than thermal. Hence, both simulation and experimentation revealed that higher laser energy input is needed for optimized melting. In addition, cellular dendrites were found to coarsen with increasing Al2O3 addition due to the decreased cooling rate. With hard particle strengthening effects, all samples showed improved hardness with 3-wt% up to 298HV and 1-wt% samples showing much improved yielding and tensile stresses of 579 and 662MPa from 316L. Corresponding microlattice built this way demonstrated a 30 and 23% increase in specific strength and energy absorption from that of 316L too.

Graphical abstract

image


http://ift.tt/2HubNS5

Τρίτη 20 Φεβρουαρίου 2018

Skin microbiota and human 3D skin models

Abstract

Although the role of the microbiota in skin homeostasis is still emerging there is growing evidence that an intact microbiota supports the skin barrier. The increasing number of research efforts that are trying to shed more light on the human skin-microbiota interaction require the use of suitable experimental models. Three-dimensional (3D) skin equivalents have been established as a valuable tool in dermatological research because they contain a fully differentiated epidermal barrier that reflects the morphological and molecular characteristics of normal human epidermis. In this review we provide an overview of current 3D skin models and illustrate the potential of 3D skin models to study the human skin-microbiota interplay.

This article is protected by copyright. All rights reserved.



http://ift.tt/2BJAtWa