Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Πέμπτη 3 Δεκεμβρίου 2015

Quality Evaluation of Zirconium Dioxide Frameworks Produced in Five Dental Laboratories from Different Countries

Abstract

Purpose

The aim of this study was to assess and compare quality as well as economic aspects of CAD/CAM high strength ceramic three-unit FDP frameworks ordered from dental laboratories located in emerging countries and Switzerland.

Material and Methods

The master casts of six cases were sent to five dental laboratories located in Thailand (Bangkok), China (Peking and Shenzhen), Turkey (Izmir), and Switzerland (Bern). Each laboratory was using a different CAD/CAM system. The clinical fit of the frameworks was qualitatively assessed, and the thickness of the framework material, the connector height, the width, and the diameter were evaluated using a measuring sensor. The analysis of the internal fit of the frameworks was performed by means of a replica technique, whereas the inner and outer surfaces of the frameworks were evaluated for traces of postprocessing and damage to the intaglio surface with light and electronic microscopes. Groups (dental laboratories and cases) were compared for statistically significant differences using Mann-Whitney U-tests after Bonferroni correction.

Results

An acceptable clinical fit was found at 97.9% of the margins produced in laboratory E, 87.5% in B, 93.7% in C, 79.2% in A, and 62.5% in D. The mean framework thicknesses were not statistically significantly different for the premolar regions; however, for the molar area 4/8 of the evaluated sites were statistically significantly different. Circumference, surface, and width of the connectors produced in the different laboratories were statistically significantly different but not the height. There were great differences in the designs for the pontic and connector regions, and some of the frameworks would not be recommended for clinical use. Traces of heavy postprocessing were found in frameworks from some of the laboratories. The prices per framework ranged from US$177 to US$896.

Conclusions

By ordering laboratory work in developing countries, a considerable price reduction was obtained compared to the price level in Switzerland. Despite the use of the standardized CAD/CAM chains of production in all laboratories, a large variability in the quality aspects, such as clinical marginal fit, connector and pontic design, as well as postprocessing traces was noted. Recommended sound handling of postprocessing was not applied in all laboratories. Dentists should be aware of the true and factitious advantages of CAD/CAM production chains and not lose control over the process.



from OroFacial Medicine via ola Kala on Inoreader http://ift.tt/1O6le54
via IFTTT

from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1NtvmsA
via IFTTT

from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1QXtyu4
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου