Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Πέμπτη 11 Φεβρουαρίου 2016

ASGE Technology Committee systematic review and meta-analysis assessing the ASGE Preservation and Incorp oration of Valuable Endoscopic Innovations thresholds for adopting real-time imaging–assisted endoscopic targeted biopsy during endoscopic surveillance of Barrett’s esophagus

Publication date: Available online 11 February 2016
Source:Gastrointestinal Endoscopy
Author(s): Nirav Thosani, Barham K. Abu Dayyeh, Prateek Sharma, Harry R. Aslanian, Brintha K. Enestvedt, Sri Komanduri, Michael Manfredi, Udayakumar Navaneethan, John T. Maple, Rahul Pannala, Mansour A. Parsi, Zachary L. Smith, Shelby A. Sullivan, Subhas Banerjee
Background and AimsEndoscopic real-time imaging of Barrett's esophagus (BE) with advanced imaging technologies enables targeted biopsies and may eliminate the need for random biopsies to detect dysplasia during endoscopic surveillance of BE. This systematic review and meta-analysis was performed by the American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee to specifically assess whether acceptable performance thresholds outlined by the ASGE Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) document for clinical adoption of these technologies have been met.MethodsWe conducted meta-analyses calculating the pooled sensitivity, negative predictive value (NPV), and specificity for chromoendoscopy by using acetic acid and methylene blue, electronic chromoendoscopy by using narrow-band imaging, and confocal laser endomicroscopy (CLE) for the detection of dysplasia. Random effects meta-analysis models were used. Statistical heterogeneity was evaluated by means of I2 statistics.ResultsThe pooled sensitivity, NPV, and specificity for acetic acid chromoendoscopy were 96.6% (95% confidence interval [CI], 95-98), 98.3% (95% CI, 94.8-99.4), and 84.6% (95% CI, 68.5-93.2), respectively. The pooled sensitivity, NPV, and specificity for electronic chromoendoscopy by using narrow-band imaging were 94.2% (95% CI, 82.6-98.2), 97.5% (95% CI, 95.1-98.7), and 94.4% (95% CI, 80.5-98.6), respectively. The pooled sensitivity, NPV, and specificity for endoscope-based CLE were 90.4% (95% CI, 71.9-97.2), 98.3% (95% CI, 94.2-99.5), and 92.7% (95% CI, 87-96), respectively.ConclusionsOur meta-analysis indicates that targeted biopsies with acetic acid chromoendoscopy, electronic chromoendoscopy by using narrow-band imaging, and endoscope-based CLE meet the thresholds set by the ASGE PIVI, at least when performed by endoscopists with expertise in advanced imaging techniques. The ASGE Technology Committee therefore endorses using these advanced imaging modalities to guide targeted biopsies for the detection of dysplasia during surveillance of patients with previously nondysplastic BE, thereby replacing the currently used random biopsy protocols.

from #Medicine-SfakianakisAlexandros via o.lakala70 on Inoreader http://ift.tt/1Ppd23k
via IFTTT




from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1PGCYWf
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου