Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Παρασκευή 6 Οκτωβρίου 2017

Clinical Diagnostic tools for vitamin D assessment

Publication date: Available online 6 October 2017
Source:The Journal of Steroid Biochemistry and Molecular Biology
Author(s): Iltaf Shah, M. Kalim Akhtar, Soleiman Hisaindee, Muhammad A. Rauf, Mohammed Sadig, S. Salman Ashraf
Vitamin D deficiency has been implicated in a plethora of diseases including rheumatoid arthritis, Parkinson's disease, Alzheimer's disease, and osteoporosis. Deficiency of this vitamin is a global epidemic affecting both developing and developed nations. Within a clinical context, the qualitative and quantitative analysis of vitamin D is therefore vital. The main metabolic markers for assessing vitamin D status in humans are the hydroxylated forms of vitamin D, 25OHD3 and 25OHD2 on account of their long half-lives within the body and excellent stability. An adequate level for healthy individuals of these hydroxylated forms is estimated to be around 20–40ng/mL of blood. There are three main analytical techniques for determining the levels of 25OHD3 and 25OHD2. The first technique is immunoassay-based and can be performed in a rapid, high throughput, automated manner, allowing as many as 240 tests per hour with the duration of each assay as little as 18minutes. Furthermore, it offers excellent sensitivity with a detection range of 3.4 to 156ng/mL. A major downside of immunoassays is that they are unable to distinguish between the various forms of vitamin D. While HPLC is a highthroughput low cost instrument it is not a very sensitive technique and cannot quantify the down stream metabolites of vitamin D. The third technique, namely liquid chromatography-mass spectrometry (LC-MS/), provides excellent sensitivity with a wide dynamic range from 0.068pg/mL to 100ng/mL. Additionally, it offers a high level of separation and permits identification of vitamin D-related metabolites. However, a huge limitation with LC/MS/MS is their poor throughput for sample analyses. As yet, there is no analytical technique which combines the fine detection capabilities of LC/MS/MS and the rapid, automated format of immunoassay, for vitamin D analyses. Future attention therefore needs to be given to this area if the current clinical diagnostic tools for vitamin D analysis are to be further improved.

Graphical abstract

image


http://ift.tt/2wBNkoh

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου