Development and application of molecularly imprinted polymer – Mn-doped ZnS quantum dot fluorescent optosensing for cocaine screening in oral fluid and serum

Publication date: 1 May 2018
Source:Talanta, Volume 181
Author(s): María Pilar Chantada–Vázquez, Carolina de–Becerra–Sánchez, Alba Fernández–del–Río, Juan Sánchez–González, Ana María Bermejo, Pilar Bermejo–Barrera, Antonio Moreda–Piñeiro
A molecularly imprinted polymer – Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL-1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL-1and 0.117mgL-1, respectively; whereas, 0.015mgL-1 (LOD) and 0.050mgL-1 (LOQ) were obtained for serum.

Graphical abstract

image


http://ift.tt/2nzRjyW

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου