Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Πέμπτη 19 Ιανουαρίου 2017

Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) in children: a randomized controlled trial †

<span class="paragraphSection"><strong>Background.</strong> Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) was introduced to adult anaesthesia to improve the safety of airway management during apnoea before intubation. The objective of our study was to determine whether THRIVE safely prolongs apnoeic oxygenation in children.<strong>Methods.</strong> This was a randomized controlled trial in 48 healthy children, with normal airways and cardiorespiratory function, in age groups 0–6 and 7–24 months, 2–5 and 6–10 yr old, presenting for elective surgery or imaging under general anaesthesia. All children were induced with sevoflurane, O<sub>2</sub>, and N<sub>2</sub>O, followed by muscle relaxation with rocuronium, and standardized preoxygenation with bag-and-mask ventilation. The control arm received jaw support during apnoea, whereas the THRIVE arm received jaw support during apnoea and age-specific flow rates. The primary outcome was to demonstrate that children allocated to THRIVE maintain transcutaneous haemoglobin saturation at least twice as long as the expected age-dependent apnoea time in the control group.<strong>Results.</strong> Both study arms (each <span style="font-style:italic;">n</span>=24) were similar in age and weight. The apnoea time was significantly shorter in the control arm: average 109.2 (95% CI 28.8) s in the control arm and 192 s in the THRIVE arm (0–6 months), 147.3 (95% CI 18.9) and 237 s (7–24 months), 190.5 (95% CI 15.3) and 320 s (2–5 yr), and 260.8 (95% CI 37.5) and 430 s (6–10 yr), respectively. Average transcutaneous haemoglobin saturation remained at 99.6% (95% CI 0.2) during THRIVE. Transcutaneous CO<sub>2</sub> increased to a similar extent in both arms, with 2.4 (95% CI 0.5) mm Hg min<sup>−1</sup> for the control arm and 2.4 (95% CI 0.4) mm Hg min<sup>−1</sup> for the THRIVE arm.<strong>Conclusion.</strong> Transnasal humidified rapid-insufflation ventilatory exchange prolongs the safe apnoea time in healthy children but has no effect to improve CO<sub>2</sub> clearance.<strong>Clinical trial registration.</strong> ACTRN12615001319561.</span>

http://ift.tt/2jELjUt

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου