Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τρίτη 5 Ιανουαρίου 2016

Laryngeal muscle activity during nasal high-frequency oscillatory ventilation in nonsedated newborn lambs.

http:--misc.karger.com-LinkOutIcons-sk_n Related Articles

Laryngeal muscle activity during nasal high-frequency oscillatory ventilation in nonsedated newborn lambs.

Neonatology. 2015;107(3):199-205

Authors: Hadj-Ahmed MA, Samson N, Nadeau C, Boudaa N, Praud JP

Abstract
BACKGROUND: We have previously shown that nasal pressure support ventilation (nPSV) can lead to an active inspiratory laryngeal narrowing in lambs. This, in turn, can limit lung ventilation and divert air into the digestive system, with potentially deleterious consequences. On the other hand, nasal high-frequency oscillatory ventilation (nHFOV) is particularly attractive in newborns, especially since, unlike nPSV, it does not require synchronization with the patient's inspiratory efforts.
OBJECTIVES: The main aim of the present study was to test the hypothesis that glottal constrictor muscle activity (EMG) does not develop during nHFOV. A secondary objective was to study laryngeal EMG during nHFOV-induced central apneas.
METHODS: Polysomnographic recordings were performed in 7 nonsedated lambs which were ventilated with increasing levels of nPSV and nHFOV at both 4 and 8 Hz, in random order. States of alertness, diaphragm and glottal muscle EMG, SpO2, and respiratory movements were continuously recorded.
RESULTS: While phasic inspiratory glottal constrictor EMG appeared with increasing nPSV levels in 6 out of 7 lambs, it was never observed with nHFOV. In addition, nHFOV at 4 Hz dramatically inhibited central respiratory drive in 4/7 lambs, with 64-100% of recording time spent in central apnea in 3 lambs. No glottal constrictor EMG was observed during these central apneas.
CONCLUSION: nHFOV does not induce glottal constrictor muscle EMG in nonsedated newborn lambs, in contrast to nPSV. This may be an additional advantage of nHFOV relative to nPSV.

PMID: 25660143 [PubMed - indexed for MEDLINE]



from Head and Neck on PubMed via xlomafota13 on Inoreader http://ift.tt/1kHYqkn
via IFTTT

from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1kI0Gs0
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου