Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Πέμπτη 7 Απριλίου 2016

Accuracy of cast posts fabricated by the direct and the indirect techniques

Publication date: Available online 7 April 2016
Source:The Journal of Prosthetic Dentistry
Author(s): Mohammad R. Rayyan, Roa'a A. Aldossari, Sarah F. Alsadun, Fatimah R. Hijazy
Statement of problemPatterns for custom cast posts and cores can be fabricated either by the direct or the indirect technique. Which technique is more accurate is unknown.PurposeThe purpose of this in vitro study was to investigate the effect of pattern fabrication technique on the accuracy of post fit.Material and methodsTen intact extracted premolar teeth with a single canal and similar dimensions received root canal treatment. The teeth were sectioned 2 mm above the cementoenamel junction. A total of 20 cast post and core patterns, 2 for each tooth, were fabricated, 10 with the direct technique and 10 with the indirect technique. Patterns were cast to produce 20 cast post and cores. Each tooth was scanned using a microcomputed tomography (μCT) system with a resolution of 14.5 μm, once with the post of the direct technique and once with the post of the indirect technique. Ct analyzer software was used to calculate the overall space between the post and canal walls and the space areas in 3 different standardized sections. The Student paired t test was used to determine any significant difference in the scores of the groups.ResultsThe overall space between the canal walls and posts made with the direct technique ranged between 7.86 and 17.39 mm3, with a mean value of 12.25 mm3, whereas with the indirect technique, the space ranged between 6.68 and 18.02 mm3, with a mean of 11.92 mm3. No significant differences were found between the results of either technique (P>.05).ConclusionsWithin the limitations of this study, neither the indirect nor direct pattern fabrication technique influenced the accuracy of post fitting.



from #Dental via xlomafota13 on Inoreader http://ift.tt/25OgZr5
via IFTTT Medicine by Alexandros G.Sfakianakis,Anapafseos 5 Agios Nikolaos,Crete 72100,Greece,tel :00302841026182 & 00306932607174



from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/1RTEJk2
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου