Breast cancer detection using single-reading of breast tomosynthesis (3D-mammography) compared to double-reading of 2D-mammography: Evidence from a population-based trial

Publication date: April 2017
Source:Cancer Epidemiology, Volume 47
Author(s): Nehmat Houssami, Daniela Bernardi, Marco Pellegrini, Marvi Valentini, Carmine Fantò, Livio Ostillio, Paolina Tuttobene, Andrea Luparia, Petra Macaskill
BackgroundMost population breast cancer (BC) screening programs use double-reading of 2D-mammography. We recently reported the screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that double-read tomosynthesis (pseudo-3D-mammography) detected more BC than double-read 2D-mammography. In this study, we compare screen-detection measures for single-reading of 3D-mammography with those for double-reading of 2D-mammography, to inform screening practice.MethodsThis is a secondary analysis based on STORM-2 which prospectively compared 3D-mammography and 2D-mammography in sequential screen-readings. Asymptomatic women ≥49 years who attended population-based screening (Trento, 2013–2015) were recruited. Participants recalled at any screen-read from parallel double-reading arms underwent further testing and/or biopsy. Single-reading of 3D-mammography, integrated with acquired or synthetized 2D-mammograms, was compared to double-reading of 2D-mammograhy alone for screen-detection measures: number of detected BCs, cancer detection rate (CDR), number and percentage of false-positive recall (FPR). Paired binary data were compared using McNemar's test.ResultsScreening detected 90, including 74 invasive, BCs in 85 of 9672 participants. CDRs for single-reading using integrated 2D/3D-mammography (8.2 per 1000 screens; 95% CI 6.5–10.2) or 2D synthetic/3D-mammography (8.4 per 1000 screens; 95% CI: 6.7–10.4) were significantly higher than CDR for double-reading of 2D-mammography (6.3 per 1000 screens; 95% CI: 4.8–8.1), P<0.001 both comparisons. FPR% for single-read 2D/3D-mammography (2.60%; 95% CI: 2.29–2.94), or single-read 2D synthetic/3D-mammography (2.76%; 95% CI: 2.45–3.11), were significantly lower than FPR% for double-read 2D-mammography (3.42%; 95% CI: 3.07–3.80), P<0.001 and P=0.002 respectively.ConclusionsSingle-reading of 3D-mammography (integrated 2D/3D or 2Dsynthetic/3D) detected more BC, and had lower FPR, compared to current practice of double-reading 2D-mammography alone − these findings have implications for population BC screening programs.



http://ift.tt/2lAlXVy

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου