Impact of Radiation Dose Reduction in Abdominal Computed Tomography on Diagnostic Accuracy and Diagnostic Performance in Patients with Suspected Appendicitis

S10766332.gif

Publication date: Available online 23 November 2017
Source:Academic Radiology
Author(s): Corinna Storz, Manuel Kolb, Jong Hyo Kim, Jakob Weiss, Wolfgang G. Kunz, Konstantin Nikolaou, Fabian Bamberg, Ahmed E. Othman
Rationale and ObjectivesTo determine the intraindividual impact of radiation dose reduction in abdominal computed tomography (CT) on diagnostic performance in patients with suspected appendicitis.Materials and MethodsThis study was approved by the institutional review board. Seventy-five patients who underwent standard contrast-enhanced abdominal CT for suspected appendicitis between 2004 and 2009 were retrospectively included. Low-dose CT reconstructions with 75%, 50%, and 25% of the original radiation dose level were generated by applying realistic reduced-dose simulation. Two blinded, independent readers assessed image quality, signal-to-noise ratio, and diagnostic confidence on each dataset. Diagnostic accuracy for detection of appendicitis and complications were calculated for each reader. Paired univariate tests were used to determine intraindividual differences.ResultsAmong 75 subjects included in the analysis (57% female, mean age: 41 ± 18 years), the prevalence of histopathologically confirmed appendicitis was 59%. Signal-to-noise ratio and subjective image quality of 50% and 25% reduced-dose CTs were significantly lower than the reference datasets (all P < .005). Appendicitis was correctly identified in all reference and low-dose datasets (sensitivity: 100%, negative predictive value: 100%). Presence of complications was correctly detected in all reference, 75%, and 50% datasets, but was decreased in 25% datasets (sensitivity: 77.8% and negative predictive value: 97.4%). Diagnostic confidence was high for original and 75% datasets, but significantly lower for 50% and 25% datasets (P < .001).ConclusionsOur results indicate that diagnostic accuracy in abdominal CT acquisitions acquired at 75% and 50% of radiation dose is maintained in patients with suspected appendicitis, whereas further reduction of radiation exposition is associated with decreased diagnostic performance.



http://ift.tt/2iLpz87

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου