Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τρίτη 12 Δεκεμβρίου 2017

Non-contrast quantitative pulmonary perfusion using flow alternating inversion recovery at 3T: A preliminary study

elsevier-non-solus.png

Publication date: February 2018
Source:Magnetic Resonance Imaging, Volume 46
Author(s): Joshua S. Greer, Christopher D. Maroules, Orhan K. Oz, Suhny Abbara, Ronald M. Peshock, Ivan Pedrosa, Ananth J. Madhuranthakam
PurposeTo demonstrate the initial feasibility of non-contrast quantitative pulmonary perfusion imaging at 3T using flow alternating inversion recovery (FAIR), and to evaluate the intra-session and inter-session reliability of FAIR measurements at 3T.Materials and methodsNine healthy volunteers were imaged using our own implementation of FAIR pulse sequence at 3T. Quantitative FAIR perfusion, both with and without larger pulmonary vessels, was correlated with global phase contrast (PC) measured blood flow in the right pulmonary artery (RPA). The same volunteers were also imaged with SPECT perfusion using technetium-99m-macroaggregated albumin and relative dispersion (RD) was assessed between FAIR and SPECT perfusion. Four additional healthy volunteers were evaluated for FAIR repeatability, using intra-class correlation coefficient (ICC) and Bland-Altman analysis. p<0.05 was considered statistically significant.ResultsFAIR perfusion across all subjects was 858±605mL/100g/min (with vessels) and 629±294mL/100g/min (without vessels) and correlated significantly with the PC measured blood flow in the RPA (r=0.62, p<0.01 with vessels; r=0.73, p<0.001 without vessels). The median RD of FAIR perfusion across all subjects was 0.73 (with vessels) and 0.49 (without vessels), compared against 0.23 with SPECT perfusion. The intra/inter-session ICC of FAIR perfusion with vessels was 0.95/0.59 and improved to 0.96/0.72, when vessels were removed.ConclusionsNon-contrast quantitative pulmonary perfusion imaging using FAIR is feasible at 3T. This may serve as a reliable method to assess regional lung perfusion at 3T to characterize and monitor treatment response in chronic lung disease without the concerns of repeated exposure to ionizing radiation or the accumulation of exogenous contrast agent.



http://ift.tt/2BfgLlr

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου