Publication date: March 2018
Source:Atmospheric Environment, Volume 176
Author(s): Wenjing Ji, Hongyu Li, Bin Zhao, Furong Deng
Sulfur and nickel have been widely used as tracers of outdoor PM2.5 (particulate matter with an aerodynamic diameter ≤ 2.5 μm) in the United States and Europe; however, their feasibility as tracers has not been verified yet in China. We aim to verify whether sulfur or nickel could be used as a tracer element and, if not, to identify a suitable tracer element for outdoor PM2.5 in China. We conduct two types of experiments, namely, preliminary and main-study experiments. We analyze 102 pairs of indoor and outdoor PM2.5 samples in Beijing. The correlation between the I/O (indoor/outdoor) ratio of an element and the I/O ratio of total PM2.5 is one of the criteria used to test whether this element can be used as a tracer element. The average concentrations of nickel are found to be below the detection limits in both preliminary and main-study tests. Thus, nickel cannot be used as a tracer element in China. Based on the correlations of elemental I/O ratios and the I/O ratio of total PM2.5 in the preliminary and main-study tests, sulfur also cannot be used as a tracer element; however, it should be feasible to use iron as a tracer element in Beijing according to the test results. The estimated infiltration factor obtained by using iron as tracer is extremely consistent with the calculations based on the mass balance model. In summary, iron is found to be more suitable as a tracer for outdoor PM2.5 in Beijing than sulfur or nickel.
Graphical abstract
http://ift.tt/2lV5ooZ