Abstract
INTRODUCTION: The opening of the round window and the insertion of the electrode array into the scala tympani during cochlear implant surgery can lead to a pressure shock of the delicate inner ear structures. By filling the tympanic cavity with Ringer Solution during these surgical steps (underwater technique), the hydrostatic pressure of the fluid acts as a smooth pressure stabilizer, avoiding a pressure shock of the inner ear structures. The aim of this retrospective study was to present long-term results of this new method of cochlear implantation in underwater technique.
METHODS: Altogether, 47 implantations in 43 patients with residual hearing at the frequencies 250, 500 and 1000 Hz in the unaided preoperative pure tone audiometry were included. A cochlear implantation via round window with a conventional full-length electrode was performed in underwater technique. Changes of residual hearing 7 weeks and 24 months after surgery were analyzed.
RESULTS: Overall postimplant hearing preservation 7 weeks after implantation was achieved in 22 ears (47%). Subsequent follow-up was performed on average 24 months after surgery (range 12 months-4.2 years) in all patients. At this late postoperative evaluation, preservation of hearing was recorded in 18 ears (38%). Neither the follow-up time nor the type of electrode had a significant impact on the postoperative hearing loss.
CONCLUSION: The underwater technique is an atraumatic cochlear implantation technique with hearing preservation rates comparable to results in literature and a very small hearing preservation decline rate over time even when using full-length CI electrodes.