Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Δευτέρα 19 Φεβρουαρίου 2018

Safety and Effectiveness of Second-Generation Drug-Eluting Stents in Patients With Left Main Coronary Artery Disease

AbstractBackground

Limited data are available on the relative performances between different types of drug-eluting stents (DES) for obstructive left main coronary artery disease (LMCAD).

Objectives

This study sought to compare effectiveness and safety profiles of various second-generation DES for LMCAD in real-world clinical practice.

Methods

Among 4,470 patients in 3, multicenter, prospective registries (IRIS-DES [Interventional Cardiology Research Incorporation Society-Drug-Eluting Stents] registry, the IRIS-MAIN [Interventional Cardiology Research Incorporation Society-Left MAIN Revascularization] registry, and the PRECOMBAT [PREmier of Randomized COMparison of Bypass Surgery versus AngioplasTy Using Drug-Eluting Stent in Patients with Left Main Coronary Artery Disease] study) treated between July 2007 and July 2015, the authors identified 2,692 patients with significant LMCAD who received second-generation DES; 1,254 with cobalt-chromium everolimus-eluting stents (CoCr-EES), 232 with biodegradable polymer biolimus-eluting stents (BP-BES), 616 with platinum-chromium EES (PtCr-EES), and 590 with Resolute zotarolimus-eluting stent (Re-ZES). The primary outcome was target-vessel failure.

Results

The observed 3-year rates of target-vessel failure were not significantly different for the different types of DES (16.7% for the CoCr-EES, 13.2% for the BP-BES, 18.7% for the PtCr-EES, and 14.7% for the Re-ZES; p = 0.15). In multiple treatment propensity score analysis, the adjusted hazard ratios (HRs) for target-vessel failure were similar in between-group comparisons of the different DES, except for the PtCr-EES versus the BP-BES (reference; HR: 1.60; 95% confidence interval: 1.01 to 2.54; p = 0.046). There were no significant differences in risk of composite of all-cause death, any myocardial infarction, or any revascularization and its individual components according to the different types of DES. Although the 3-year incidence of stent thrombosis was considerably low (≤1.0%) for all types of DES, between-group differences were observed, generally favoring the EES platforms.

Conclusions

In this pooled analysis of 3 prospective registries involving unrestricted use of various second-generation DES for LMCAD, we found no significant between-group differences in 3-year risk of target-vessel failure, except for a higher risk of primary outcome with PtCr-EES compared to BP-BES. (Evaluation of the First, Second, and New Drug-Eluting Stents in Routine Clinical Practice [IRIS-DES]; NCT01186133)



http://ift.tt/2oiNRbP

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου