Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Παρασκευή 11 Μαΐου 2018

Comparison of dosimetric and clinical outcomes between short- and long-channel cylinder applicators for vaginal brachytherapy in intermediate- and high-risk endometrial cancer

alertIcon.gif

Publication date: Available online 11 May 2018
Source:Brachytherapy
Author(s): Michael Z. Kharouta, Nghia Pham, Karina Nieto, Murat Surucu, Michael L. Mysz, Kevin Albuquerque, Abigail Winder, Margaret Liotta, Ronald K. Potkul, William Small, Matthew M. Harkenrider
PurposeVaginal brachytherapy (VBT) using a cylinder applicator is a standard treatment of intermediate- and high-risk endometrial cancer. We conducted a retrospective study of the dosimetric and clinical outcomes at our institution with 2 single-channel applicators in patients receiving VBT.Methods and MaterialsOne hundred thirty-six patients with endometrial cancer treated from 2006 to 2016 receiving VBT after definitive surgery were evaluated. Two cylinders were used with the distal dwell position 7.1–12.8 mm from the apex varying by diameter (short channel), and 3.2 mm from the apex (long channel). We prescribed 18–26 Gy in 3–4 fractions at 0.5 cm depth. Measurements of the distance from the apex to the prescription isodose line were taken from CT imaging. Student's t test and the Wilcoxon rank-sum test were used with corrections for multiple comparisons.ResultsPatients had International Federation of Gynecology and Obstetrics 2009 Stage I-II disease (70 Stage IA, 58 Stage IB, 9 Stage II). Mean cylinder apex dose was 95.2% and 154.7% of prescription (p < 0.001), and mean distance from apex to the prescription isodose line was 0.54 mm and 3.5 mm (p < 0.001) for the short- and long-channel cylinders, respectively. There were no significant differences in any toxicity between cylinders. Four patients (2.9%) had vaginal recurrence, all of whom were treated with the short-channel cylinder. Cylinder type was not associated with vaginal recurrence (p = 0.27).ConclusionsA cylinder applicator with a distal dwell position closer to the apex results in higher doses to the vaginal cuff and increased D2cc to the bladder. All four recurrences were in the short-channel cylinder. Additional investigation into applicator design and impact on patient outcomes in larger cohorts with sufficient followup is warranted.



https://ift.tt/2rx0LVZ

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου