Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τετάρτη 27 Ιουνίου 2018

Fat spectral modeling on triglyceride composition quantification using chemical shift encoded magnetic resonance imaging

Publication date: October 2018
Source:Magnetic Resonance Imaging, Volume 52
Author(s): Gregory Simchick, Amelia Yin, Hang Yin, Qun Zhao
PurposeTo explore, at a high field strength of 7T, the performance of various fat spectral models on the quantification of triglyceride composition and proton density fat fraction (PDFF) using chemical-shift encoded MRI (CSE-MRI).MethodsMR data was acquired from CSE-MRI experiments for various fatty materials, including oil and butter samples and in vivo brown and white adipose mouse tissues. Triglyceride composition and PDFF were estimated using various a priori 6- or 9-peak fat spectral models. To serve as references, NMR spectroscopy experiments were conducted to obtain material specific fat spectral models and triglyceride composition estimates for the same fatty materials. Results obtained using the spectroscopy derived material specific models were compared to results obtained using various published fat spectral models.ResultsUsing a 6-peak fat spectral model to quantify triglyceride composition may lead to large biases at high field strengths. When using a 9-peak model, triglyceride composition estimations vary greatly depending on the relative amplitudes of the chosen a priori spectral model, while PDFF estimations show small variations across spectral models. Material specific spectroscopy derived spectral models produce estimations that better correlate with NMR spectroscopy estimations in comparison to those obtained using non-material specific models.ConclusionAt a high field strength of 7T, a material specific 9-peak fat spectral model, opposed to a widely accepted or generic human liver model, is necessary to accurately quantify triglyceride composition when using CSE-MRI estimation methods that assume the spectral model to be known as a priori information. CSE-MRI allows for the quantification of the spatial distribution of triglyceride composition for certain in vivo applications. Additionally, PDFF quantification is shown to be independent of the chosen a priori spectral model, which agrees with previously reported results obtained at lower field strengths (e.g. 3T).

Graphical abstract

image


https://ift.tt/2yP5msz

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου