Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Σάββατο 2 Ιουνίου 2018

In vitro comparison of an Er:YAG laser-activated bleaching system with different light-activated bleaching systems for color change, surface roughness, and enamel bond strength

Abstract

To compare an Er:YAG laser-activated bleaching system with different light-activated in-office bleaching systems for color change, surface roughness, and post-bleaching enamel bond strength. 51 enamel slabs were prepared from the sound buccal enamel of extracted bovine teeth. The teeth were randomly divided into three groups according to different light-activated office bleaching systems (n = 17): diode laser (Epic, Biolase) (940 nm, 7 W, continuous mode), Er:YAG laser (LightWalker, Fotona) (2940 nm, 50 mJ, 10 Hz, 1000 μs), and LED (Radii Plus) (440–480 nm, 1500 mW/cm2). All systems were used with their compatible bleaching agents according to manufacturers' recommendations. The tooth color and surface roughness (Ra) were assessed at baseline and after bleaching using a spectrophotometer and a surface profilometer, respectively. The color change was determined by the CIE L*a*b* system (ΔE, ΔL*, Δa*, Δb*). Kruskal-Wallis test was used for color change whereas Kruskal-Wallis and Wilcoxon tests were used to analyze the roughness data. For shear bond strength test (SBS), composite cylinders were bonded on bleached enamel samples 14 days after bleaching procedures and stored in water (37 °C). Specimens were then debonded with a universal testing machine at 1 mm/min and data were analyzed by using Kruskal-Wallis test. All the tested bleaching systems were effective on color change (ΔE > 3.3) and produced similar color change (p > 0.05). There were no significant differences among the Ra values of the groups neither at baseline nor after bleaching (p > 0.05). However, comparing the baseline and after bleaching Ra values, a significant increase was observed for all tested groups (p < 0.05). Significant differences were also found among all systems for SBS (p < 0.05). The highest values were obtained in Er:YAG group, whereas the LED group revealed the lowest values (p < 0.05). All tested bleaching systems were effective on tooth whitening, whereas they all led to an increase on surface roughness. Although the current Er:YAG laser-activated bleaching system did not differ from other tested bleaching systems according to color change and surface roughness, it appears to provide better results in terms of SBS.



https://ift.tt/2J8rvCP

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου