Extremely common radiographic finding of cochlear nerve deficiency among infants with prelingual single-sided deafness and its clinical implications

Publication date: Available online 10 July 2018

Source: International Journal of Pediatric Otorhinolaryngology

Author(s): Woongsang Sunwoo, Won-Wook Lee, Byung Yoon Choi

Abstract
Objectives

To clarify the common radiographic findings of audiologically documented prelingual single-sided deafness (SSD) and identify the prevalence of cochlear nerve deficiency (CND) in SSD infants referred from the newborn hearing screening program.

Methods

Between March 2012 and March 2017, the records of all infants referred to our otology clinic after undergoing newborn hearing screening program were retrospectively reviewed. Twenty-four consecutive well infants without risk factors who had a confirmed diagnosis of prelingual SSD under the age of 1 year and who underwent internal auditory canal (IAC) magnetic resonance imaging (MRI) were included. The sizes of cochlear nerve (CN), IAC, and cochlear nerve canal (CNC) were measured on MRI. The presence of CND was visually determined by comparing the CN size to the ipsilateral facial nerve (FN) in the affected side via an oblique sagittal view of IAC MRI and defined when CN was absent or smaller than FN.

Results

CND was seen in all 24 deaf ears (100%) on MRI. There was one with incomplete partition type I, and another with combined cochleovestibular nerve absence. Twenty-four subjects demonstrated either an absent (20/24, 83.3%) or small (4/24, 16.7%) CN. When the absent and small CN groups were compared, the former group had a higher prevalence of narrow CNC and narrow IAC. Of the 20 infants without identifiable CN on the affected side, 17 (85%) had narrow IAC and 17 (85%) had narrow CNC. In the 20 ears with absent CN, only one had both normal-sized IAC and CNC.

Conclusion

The contribution of CND to prelingual SSD in Korean infants reached 100%, according to IAC MRI alone.