Perceptual Evaluation of Vocal Fold Vibratory Asymmetry

xlomafota13 shared this article with you from Inoreader

Objectives

Laryngeal vibratory asymmetry occurring with paresis may result in a perceptually normal or abnormal voice. The present study aims to determine the relationships between the degree of vibratory asymmetry, acoustic measures, and perception of sound stimuli.

Study Design

Animal Model of Voice Production, Perceptual Analysis of Voice.

Methods

In an in vivo canine model of phonation, symmetric and asymmetric laryngeal vibration were obtained via graded unilateral recurrent laryngeal nerve (RLN) stimulation simulating near paralysis to full activation. Phonation was performed at various contralateral RLN and bilateral superior laryngeal nerve stimulation levels. Naïve listeners rated the perceptual quality of 182 unique phonatory samples using a visual sort-and-rate task. Cepstral peak prominence (CPP) was calculated for each phonatory condition. The relationships among vibratory symmetry, CPP, and perceptual ratings were evaluated.

Results

A significant relationship emerged between RLN stimulation and perceptual rating, such that sound samples from low RLN levels were preferred to those from high RLN levels. When symmetric vibration was achieved at mid-RLN stimulation, listeners preferred samples from symmetric vibration over those from asymmetric vibration. However, when symmetry was achieved at high RLN levels, a strained voice quality resulted that listeners dispreferred over asymmetric conditions at lower RLN levels. CPP did not have a linear relationship with perceptual ratings.

Conclusions

Laryngeal vibratory asymmetry produces variable perceptual differences in phonatory sound quality. Though CPP has been correlated with dysphonia in previous research, its complex relationship with quality limits its usefulness as clinical marker of voice quality perception.

Level of Evidence

NA, basic science Laryngoscope, 2021