This is the first study to magnetically target gadolinium contrast to the inner ear as an effective, minimally-invasive, local delivery technique that can be tracked by magnetic resonance imaging (MRI). Better accumulation of gadolinium contrast allows better visualization and quantification of endolymphatic hydrops.
Objectives
1. Determine the feasibility and efficiency of local magnetic targeting delivery of gadolinium (Gad) contrast to the inner ear in rodents. 2. Assess any potential ototoxicity of magnetic targeting delivery of Gad in the inner ear. 3. Study the utility of magnetic targeting delivery of Gad to visualize and quantify endolymphatic hydrops (EH) in a transgenic mouse model.
Study Design
Controlled in vivo animal model study.
Methods
Paramagnetic Gad was locally delivered to the inner ear using the magnetic targeting technique in both rat and mouse models. Efficiency of contrast delivery was assessed using magnetic resonance imaging (MRI). Ototoxicity of Gad was examined with histology of the cochlea and functional audiological tests. The Phex mouse model was used to study EH, hearing loss, and balance dysfunction. Magnetic targeting delivery of Gad contrast was used in the Phex mouse model to visualize the effects of EH using MRI.
Results
Magnetic targeting improved the delivery of Gad to the inner ear and the technique was reproducible in both rat and mouse models. The delivery method did not result in microstructural damage or any significant hearing loss in a normal animal. Magnetic targeting of Gad in the Phex mouse model allowed detailed visualization and quantification of EH.
Conclusion
This study provided the first evidence of the effectiveness and efficiency of the local magnetic targeting delivery of gadolinium contrast to the inner ear and its application to the visualization and quantification of EH. Laryngoscope, 2022
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου