Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Πέμπτη 30 Ιουνίου 2016

Six-year clinical performance of etch-and-rinse and self-etch adhesives

Publication date: Available online 25 June 2016
Source:Dental Materials
Author(s): Lee W. Boushell, Harald O. Heymann, Andre V. Ritter, John R. Sturdevant, Edward J. Swift, Aldridge D. Wilder, Yunro Chung, Cynthia A. Lambert, Ricardo Walter
ObjectiveTo evaluate the 6-year clinical performance of Xeno IV, Xeno III, and XP Bond adhesives in the restoration of non-carious cervical lesions (NCCLs).MethodsThis was a randomized controlled clinical trial where 39 participants met the inclusion/exclusion criteria and were enrolled. Lesions restored were notch-shaped NCCLs. Prior to adhesive procedures, NCCLs were roughened. No enamel bevel was placed and no mechanical retention was created. Adhesive systems were applied following manufacturer's instructions and the NCCLs were restored with composite resin (TPH3). Restorations were finished immediately after placement and scored with regard to retention, marginal discoloration, marginal adaptation, sensitivity, and secondary caries using modified USPHS criteria. Descriptive statistics were performed. Logistic regression models were performed for each outcome separately with compound symmetry correlation structure where teeth were clustered by participants. All analyses were conducted using SAS 9.2.ResultsThe 6-year recall rate was 77.5% of the restorations (76.9% of the participants). No statistical differences were found between adhesives for retention, marginal discoloration, and marginal adaptation. Restorations failed by loss of retention (16.7%, 27.6%, and 11.8% of Xeno IV, Xeno III, and XP Bond restorations, respectively) and marginal discoloration (7.4% of Xeno IV restorations). For every unit increase in restoration volume it was 1.31 (95%C.I. 1.05, 1.63, P=0.01) times more likely that the restoration retention would be maintained.SignificanceThe tested adhesive systems presented similar clinical performance after six years of service, with annual failure rates of 2.8%, 4.6%, and 2.0% for Xeno IV, Xeno III, and XP Bond, respectively.



http://ift.tt/29irIDO



from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/295eZ4C
via IFTTT

from #Med Blogs by Alexandros G.Sfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/29tZnt5
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου