Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Κυριακή 18 Δεκεμβρίου 2016

The effects of tracheal tube cuffs filled with air, saline or alkalinised lidocaine on haemodynamic changes and laryngotracheal morbidity in children: a randomised, controlled trial.

Related Articles

The effects of tracheal tube cuffs filled with air, saline or alkalinised lidocaine on haemodynamic changes and laryngotracheal morbidity in children: a randomised, controlled trial.

Anaesthesia. 2016 Dec 17;:

Authors: Soares SM, Arantes VM, Módolo MP, Dos Santos VJ, Vane LA, Navarro E Lima LH, Braz LG, do Nascimento P, Módolo NS

Abstract
We studied the effects of tracheal tube cuffs filled with air, saline or alkalinised lidocaine on haemodynamic changes during tracheal extubation and postoperative laryngotracheal morbidity in children. We randomly allocated 164 children aged 3-13 years undergoing general anaesthesia to one of four groups; tracheal tube cuffs filled with air (n = 41); saline (n = 41); alkalinised lidocaine 0.5% (n = 41); or alkalinised lidocaine 1% (n = 41). Intracuff pressure was monitored and maintained below 20 cmH2 O. The mean (SD) increases in systolic blood pressure after tracheal extubation compared with before extubation were 10.9 (10.8) mmHg, 7.3 (17.7) mmHg, 4.1 (10.5) mmHg and 1.9 (9.5) mmHg in the air, saline, 0.5% and 1% alkalinised lidocaine groups, respectively (p = 0.021). The mean (SD) increases in diastolic blood pressure after tracheal extubation compared with before extubation were 3.9 (9.7) mmHg, 7.9 (14.6) mmHg, 0.7 (10.4) mmHg and 3.6 (6.9) mmHg in the air, saline, 0.5% and 1% alkalinised lidocaine groups, respectively (p = 0.019). The mean (SD) increases in heart rate after tracheal extubation compared with before extubation were 14.2 (7.6) beats.min(-1) , 15.5 (13.1) beats.min(-1) , 5.2 (9.6) beats.min(-1) and 4.1 (6.6) beats.min(-1) in the air, saline, 0.5% and 1% alkalinised lidocaine groups, respectively (p < 0.001). The incidence of sore throat 8 h after tracheal extubation was 22.0% in the air-filled group, 9.8% in the saline group, 4.9% in the 0.5% alkalinised lidocaine group and 2.4% in the 1% alkalinised lidocaine group, p = 0.015. We conclude that filling the tracheal tube cuff with alkalinised lidocaine-filled reduces the haemodynamic response to tracheal extubation and postoperative laryngotracheal morbidity in children.

PMID: 27987218 [PubMed - as supplied by publisher]



http://ift.tt/2gYWbwy

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου