Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Κυριακή 9 Απριλίου 2017

A Novel Self-Expandable, Radioactive Airway Stent Loaded with (125)I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

Related Articles

A Novel Self-Expandable, Radioactive Airway Stent Loaded with (125)I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

Cardiovasc Intervent Radiol. 2017 Apr 07;:

Authors: Wang Y, Guo JH, Zhu GY, Zhu HD, Chen L, Lu J, Wang C, Teng GJ

Abstract
PURPOSE: Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with (125)I seeds in healthy beagle dog.
MATERIALS AND METHODS: Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with (125)I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting.
RESULTS: All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of (125)I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope.
CONCLUSIONS: This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with (125)I seeds in healthy beagle dog.

PMID: 28389860 [PubMed - as supplied by publisher]



http://ift.tt/2ntXtTe

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου