Purpose
To evaluate the reproducibility and interuser agreement of measurements of choroidal neovascularisation in optical coherence tomography angiography (OCTA).
DesignProspective non-interventional study.
MethodsConsecutive patients, presenting with neovascular age-related macular degeneration (AMD), underwent two sequential OCTA examinations (AngioVue, Optovue, Fremont, California, USA), performed by the same trained examiner. Neovascular lesion area was then measured on both examinations in the choriocapillaris automatic segmentation by two masked readers, using the semiautomated measuring software embedded in the instrument. Two measuring features were used: the first corresponding to the total manually contoured lesion area with the flow draw tool (select area) and the second to the total area of solely vessels with high flow within the lesion (vessel area). These measurements were then compared in order to assess both the reproducibility of OCTA examination and the interuser agreement with the embedded software.
ResultsForty-eight eyes of 46 patients (77.4 mean age,+/-8.2 SD, range from 62 to 95 years old, eight men, 38 women) were included in our study. Mean choroidal neovascularisation area was of 0.72+/-0.7 mm2 for the first measurement and 0.75+/-0.76 mm2 for the second measurement; difference between the first and the second measurement was 0.03 mm2. Intrauser agreement was of 0.98 (CI 0.98 to 0.99) for both 'vessel area' and 'select area' features. Interuser agreement was of 0.98 (CI 0.97 to 0.99) for 'select area' and 'vessel area' features.
ConclusionOur data suggest that OCTA provide reproducible imaging for evaluation of the neovascular size in the setting of AMD.
http://ift.tt/2iJtJzR
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου