Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Παρασκευή 24 Νοεμβρίου 2017

Dictionary-based Fiber Orientation Estimation with Improved Spatial Consistency

Publication date: Available online 23 November 2017
Source:Medical Image Analysis
Author(s): Chuyang Ye, Jerry L. Prince
Diffusion magnetic resonance imaging (dMRI) has enabled in vivo investigation of white matter tracts. Fiber orientation (FO) estimation is a key step in tract reconstruction and has been a popular research topic in dMRI analysis. In particular, the sparsity assumption has been used in conjunction with a dictionary-based framework to achieve reliable FO estimation with a reduced number of gradient directions. Because image noise can have a deleterious effect on the accuracy of FO estimation, previous works have incorporated spatial consistency of FOs in the dictionary-based framework to improve the estimation. However, because FOs are only indirectly determined from the mixture fractions of dictionary atoms and not modeled as variables in the objective function, these methods do not incorporate FO smoothness directly, and their ability to produce smooth FOs could be limited. In this work, we propose an improvement to Fiber Orientation Reconstruction using Neighborhood Information (FORNI), which we call FORNI+; this method estimates FOs in a dictionary-based framework where FO smoothness is better enforced than in FORNI alone. We describe an objective function that explicitly models the actual FOs and the mixture fractions of dictionary atoms. Specifically, it consists of data fidelity between the observed signals and the signals represented by the dictionary, pairwise FO dissimilarity that encourages FO smoothness, and weighted ℓ1-norm terms that ensure the consistency between the actual FOs and the FO configuration suggested by the dictionary representation. The FOs and mixture fractions are then jointly estimated by minimizing the objective function using an iterative alternating optimization strategy. FORNI+ was evaluated on a simulation phantom, a physical phantom, and real brain dMRI data. In particular, in the real brain dMRI experiment, we have qualitatively and quantitatively evaluated the reproducibility of the proposed method. Results demonstrate that FORNI+ produces FOs with better quality compared with competing methods.

Graphical abstract

image


http://ift.tt/2i0neZX

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου