Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τετάρτη 7 Φεβρουαρίου 2018

Diagnostic yield of standard-wake and sleep EEG recordings

S13882457.gif

Publication date: Available online 3 February 2018
Source:Clinical Neurophysiology
Author(s): Pirgit Meritam, Elena Gardella, Jørgen Alving, Daniella Terney, Melita Cacic Hribljan, Sándor Beniczky
ObjectiveTo investigate whether Posterior Dominant Rhythm (PDR) can be reliably assessed in sleep-EEG recordings and to investigate the diagnostic yield of standard-wake and sleep-recordings.MethodsEEG recordings of 303 consecutive patients aged 18-88 years were analyzed. All patients had both standard-wake and sleep-recordings, including patients who had abnormal standard recordings. Melatonin was used in 6% of sleep EEGs, and sleep deprivation in 94%. The mean duration of sleep was 41 minutes. We measured the PDR frequency in standard and sleep-recordings, both before and after sleep. We compared the diagnostic yield of standard-wake and sleep EEG recordings.ResultsCompared to standard EEG, sleep-recordings showed a significantly lower PDR frequency, both when measured before and after sleep (p<0.001). One-hundred-fifty-six patients (51%) had normal standard recordings, and 35 of them (22%) had abnormal findings in the sleep-recording. One-hundred-forty-seven patients had abnormal standard recordings and in 16 of them (11%) these abnormalities were not present in sleep-recording.ConclusionsPDR is significantly slower in the wake periods of sleep-recordings, compared to standard wake recordings.SignificanceSleep and standard wake recordings are complementary.



http://ift.tt/2FVmiMQ

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου