Assessment of Breast Asymmetry in Adolescent Idiopathic Scoliosis Using an Automated 3D Body Surface Measurement Technique

Publication date: May 2017
Source:Spine Deformity, Volume 5, Issue 3
Author(s): Joyce Ramsay, Lama Seoud, Soraya Barchi, Farida Cheriet, Julie Joncas, Isabelle Turgeon, Philippe Debanné, Isabelle Trop, Hubert Labelle, Stefan Parent
Study designCohort study.ObjectivesTo assess breast asymmetry (BA) directly with 3D surface imaging and to validate it using MRI values from a cohort of 30 patients with significant adolescent idiopathic scoliosis (AIS). Also, to study the influence of posture (prone vs standing) on BA using the automated method on both modalities.Summary of background dataBA is a common concern in young female patients with AIS. In a previous study using MRI, we found that the majority of patients with significant AIS experienced BA of up to 21% in addition to their chest wall deformity. MRI is costly and not always readily available. 3D surface topography, which offers fast and reliable breast acquisitions without radiation or distortion of the body surface, is an alternative method in the clinical setting.MethodsThirty patients with AIS were enrolled in the study on the basis of their thoracic curvature, skeletal and breast maturity, without regard to their perception of their BA. Each patient underwent two imaging studies of their torso: a 3D trunk surface topography and a breast MRI. An automated breast volume measuring method was proposed using a program developed with Matlab programming.ResultsStrong correlations were obtained when comparing the proposed method to the MRI on the left breast volumes (LBV) (r = 0.747), the right breast volumes (RBV) (r = 0.805) and the BA (r = 0.614). Using the same method on both imaging modalities also yielded strong correlation coefficients on the LBV (r = 0.896), the RBV (r = 0.939) and the BA (r = 0.709).ConclusionsThe proposed 3D body surface automated measurement technique is feasible clinically and correlates very well with breast volumes measured using MRI. Additionally, breast volumes remain comparable despite being measured in different body positions (standing and prone) in a young cohort of AIS patients.Level of EvidenceLevel IV.



http://ift.tt/2pkfl2O

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου