NEW MODEL FOR MINES AND TRANSPORTATION TUNNELS EXTERNAL DOSE CALCULATION USING MONTE CARLO SIMULATION.
Radiat Prot Dosimetry. 2017 Apr 13;:1-7
Authors: Allam KA
Abstract
In this work, a new methodology is developed based on Monte Carlo simulation for tunnels and mines external dose calculation. Tunnels external dose evaluation model of a cylindrical shape of finite thickness with an entrance and with or without exit. A photon transportation model was applied for exposure dose calculations. A new software based on Monte Carlo solution was designed and programmed using Delphi programming language. The variation of external dose due to radioactive nuclei in a mine tunnel and the corresponding experimental data lies in the range 7.3-19.9%. The variation of specific external dose rate with position in, tunnel building material density and composition were studied. The given new model has more flexible for real external dose in any cylindrical tunnel structure calculations.
PMID: 28419332 [PubMed - as supplied by publisher]
http://ift.tt/2o2Uxxh