Macintosh Blade Videolaryngoscopy Combined With Rigid Bonfils Intubation Endoscope Offers a Suitable Alternative for Patients With Difficult Airways

BACKGROUND: In the armamentarium of an anesthesiologist, videolaryngoscopy is a valuable addition to secure the airway. However, when the videolaryngoscope (VLS) offers no solution, few options remain. Earlier, we presented an intubation technique combining Macintosh blade VLS and Bonfils intubation endoscope (BIE) for a patient with a history of very difficult intubation. In the present study, we evaluated this technique to establish whether it is a valuable alternative. METHODS: In this single-blinded nonrandomized study, 38 patients with a history of difficult intubation or 1 or more predictors of difficult intubation, scoring a Cormack & Lehane (C&L) grade III or IV using Macintosh blade VLS, were included. Patients were intubated combining the VLS with the BIE. The C&L grade was scored 3 times during (1) direct laryngoscopy; (2) indirect videolaryngoscopy; and (3) using the combined technique (VLS + BIE). Afterward, 2 blinded anesthesiologists assessed the C&L grade using the pictures taken during the procedure. RESULTS: Data of 38 patients were analyzed. An improvement of the C&L grade with the combined technique occurred in 33 of 38 patients (86.8%; 95% confidence interval, 71.9%–95.6%). Reviewer 1 reported an improvement of the C&L grade with the combined technique in 37 of 38 patients. Reviewer 2 reported improvement in 33 and deterioration in 2 of the patients. No complications occurred. CONCLUSIONS: The combined use of a VLS with Macintosh blade and BIE gives the anesthesiologist a valuable alternative intubation option in patients with extremely difficult airways. Accepted for publication November 2, 2017. Funding: None of the study members has received funding from the device manufacturer of the Bonfils intubation endoscope. All devices used for the study were readily available from the department. No funding was obtained from the device manufacturers. The authors declare no conflicts of interest. Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's website (http://ift.tt/KegmMq). Clinical trial registration: ClinicalTrials.gov—NCT01691703. Reprints will not be available from the authors. Address correspondence to Barbe M. Pieters, MD, PhD, Department of Anesthesiology, University Medical Centre Utrecht, Postbus 85090, 3508 AB Utrecht, the Netherlands. Address e-mail to bmapieters@gmail.com. © 2017 International Anesthesia Research Society

http://ift.tt/2BfMCDr

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου