Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Σάββατο 13 Ιανουαρίου 2018

Diagnostic Usefulness of Combination of Diffusion-weighted Imaging and T2WI, Including Apparent Diffusion Coefficient in Breast Lesions

S10766332.gif

Publication date: Available online 12 January 2018
Source:Academic Radiology
Author(s): Keum Won Kim, Cherie M. Kuzmiak, Young Joong Kim, Jae Young Seo, Hae Kyoung Jung, Mu-Sik Lee
PurposeThis study aimed to compare the diagnostic values of a combination of diffusion-weighted imaging and T2-weighted imaging (DWI-T2WI) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and to evaluate the correlation of DWI with the histologic grade in breast cancer.Materials and MethodsThis study evaluated a total of 169 breast lesions from 136 patients who underwent both DCE-MRI and DWI (b value, 1000s/mm2). Morphologic and kinetic analyses for DCE-MRI were classified according to the Breast Imaging-Reporting and Data System. For the DWI-T2WI set, a DWI-T2WI score for lesion characterization that compared signal intensity of DWI and T2WI (benign: DWI-T2WI score of 1, 2; malignant: DWI-T2WI score of 3, 4, 5) was used. The diagnostic values of DCE-MRI, DWI-T2WI set, and combined assessment of DCE and DWI-T2WI were calculated.ResultsOf 169 breast lesions, 48 were benign and 121 were malignant (89 invasive ductal carcinoma, 24 ductal carcinoma in situ, 4 invasive lobular carcinoma, 4 mucinous carcinoma). The mean apparent diffusion coefficient (ADC) of invasive ductal carcinoma (0.92 ± 0.19 × 10−3 mm2/s) and ductal carcinoma in situ (1.11 ± 0.13 × 10−3 mm2/s) was significantly lower than the value seen in benign lesions (1.36 ± 0.22 × 10−3 mm2/s). The specificity, positive predictive value (PPV), and accuracy of DWI-T2WI set and combined assessment of DCE and DWI-T2WI (specificity, 87.5% and 91.7%; PPV, 94.3% and 96.2%; accuracy, Az = 0.876 and 0.922) were significantly higher than those of the DCE-MRI (specificity, 45.8%; PPV, 81.7%; accuracy, Az = 0.854; P < .05). A low ADC value and the presence of rim enhancement were associated with a higher histologic grade cancer (P < .05).ConclusionCombining DWI, T2WI, and ADC values provides increased accuracy for differentiation between benign and malignant lesions, compared with DCE-MRI. A lower ADC value was associated with a higher histologic grade cancer.



http://ift.tt/2FxKcOR

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου