Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Τρίτη 5 Ιουνίου 2018

Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences

alertIcon.gif

Publication date: September–October 2018
Source:Clinical Imaging, Volume 51
Author(s): Kevin Y. Wang, Tomas A. Uribe, Christie M. Lincoln
PurposeInfratentorial lesions in patients with multiple sclerosis are associated with long-term disability. Two-dimensional fluid-attenuated inversion recovery demonstrates poor infratentorial lesion detection when compared to T2-weighted spin echo. Evidence of improved detection with 3D fluid-attenuated inversion recovery has been conflicting. This study compares the infratentorial lesion detection performance, observer performance, and signal and contrast properties between T2-weighted spin echo, 2D, and 3D fluid-attenuated inversion recovery.MethodsTwo board-certified radiologists independently reviewed and counted infratentorial lesions from 85 brain MRIs in patients with clinically definite multiple sclerosis and concurrent 3D, 2D fluid-attenuated inversion recovery, and T2-weighted spin echo sequences. Contrast-to-noise and signal-to-noise ratios were measured for 25 MRIs. Wilcoxon signed-rank test was used for pairwise comparisons of the combined average infratentorial lesion count, contrast-to-noise, and signal-to-noise ratios, and was adjusted for three pairwise comparisons using Bonferroni correction. A corrected p value < 0.05 was considered statistically significant.ResultsThe number of lesions on 3D fluid-attenuated inversion recovery was significantly higher than those on 2D (p < 0.001) and T2-weighted spin echo (p < 0.001). Results of contrast-to-noise and signal-to-noise ratios were overall mixed and predominantly not concordant with lesion count findings, with T2-weighted spin echo demonstrating the highest signal-to-noise ratios and contrast-to-noise ratio of lesion compared with white matter but the lowest contrast-to-noise ratio of lesion compared with gray matter.ConclusionThe 3D fluid-attenuated inversion recovery sequence addresses the disadvantage of poor infratentorial lesion detection on 2D, while still maintaining the advantage over T2-weighted spin echo in the detection of lesions adjacent to the cerebrospinal fluid.



https://ift.tt/2Jr6xm3

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου