Σφακιανάκης Αλέξανδρος
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5 Άγιος Νικόλαος
Κρήτη 72100
00302841026182
00306932607174
alsfakia@gmail.com

Αρχειοθήκη ιστολογίου

! # Ola via Alexandros G.Sfakianakis on Inoreader

Η λίστα ιστολογίων μου

Δευτέρα 3 Σεπτεμβρίου 2018

Tri-dimensional model for ventilation tube permeability

Abstract

Purpose

Ventilation tubes (VT) in the tympanic membrane expose the middle ear (ME) to the external auditory canal and its content. It carries the risk of penetration of contaminated material and could provide a pathway for the delivery of drugs into the ME. The aim of this study was to use a printed 3D-model of the external auditory canal (EAC) and ME to assess the permeability of various VTs to different fluids.

Methods

CT scan of the external and ME was 3D-reconstructed and printed. Five different types of VT were inserted in the model's tympanic membrane and the minimal pressure for penetration to the ME was measured. Liquids with different viscosities, including commonly used ear drops, were tested.

Results

Water passed through the standard 1.14 mm diameter VTs after filling the EAC with a volume of 2 ml and through a narrower grommet or a T-tube after filling the canal with 2.5 ml. Soapy-water had the highest penetration in all VTs (1–2 ml). The initial volume of dexamethasone needed for penetration was 2.5 ml in the standard tubes. It did not pass at any volume through the narrow grommet or the T-tube.

Conclusion

In the printed 3D-model, the volume of most solutions, including water, required to provide enough pressure in order to pass through the VTs was as high as the EAC volume or exceeded it. Soapy water had the highest penetrance while Dexamethasone needed volume of 2.5 ml to pass through the VT, questioning its reliability as a passive drug delivery channel to the ME.



https://ift.tt/2wDiT30

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αρχειοθήκη ιστολογίου